The LCA3 centralized lubrication unit, designed for use in the volumetric type system, comes equipped with the MLB015W (03W) pump featuring a pressure displacement mechanism.
Various models are available based on the standard unit, such an as a LCA3 with in IC timer, pressure switch or a float switch option.
Technical Features
Discharge Pressure (MPa)
1.5 (15 Bar)
Discharge Volume (L/min)
50 Hz
0.16
60 Hz
0.19
Viscosity Range (cSt)
20-2000
Motor Output x Poles (W) x (P)
25 x 4
Current (A)
200 V 50 Hz
0.26
200 V 60 Hz
0.27
220 V 60Hz
0.27
IC Timer Type Y15
2-180 mins (Initially set to 4 min)
Level Switch OLV
Max. Voltage
AC250V
Max. Current
AC0.33A
Contact Point
Under 0.1Ohm
Pressure Switch GFB12
Max. Voltage
AC250V
Max. Current
10 A
Models
Model
Type
Pump
Tank
IC Timer
(with monitoring function)
Pressure Switch
Float Switch
Abnormality Detection Lamp
"Instant"
Lube Button
MLB015W
TY4P
TY6P
Y15
GFB12
OLV*
LCA30101F(C)
X
X
–
X
X
X
X
X
LCA30131E(C)
X
X
–
–
X
X
–
–
LCA30133E(C)
X
X
–
–
X
–
–
–
LCA30134E(C)
X
X
–
–
–
X
–
–
LCA30100E(C)
X
X
–
–
–
–
–
–
LCA30201F(C)
X
–
X
X
X
X
X
X
LCA30231E(C)
X
–
X
–
X
X
–
–
LCA30233E(C)
X
–
X
–
X
–
–
–
LCA30234E(C)
X
–
X
–
–
X
–
–
LCA30200E(C)
X
–
X
–
–
–
–
–
* The last alphabetical character of the model code refers to the unit's power supply.
E: Three phase 200 / 200•220V
C: Single phase 100 / 100V
F: Single phase 200 / 200•220V
* The Y15 timer utilizes single phase 100V or 200V
* The "F" option is only available for units with a Y15 Timer.
* Models not listed above are also available with different motors (pumps) and tanks. Please contact NEUBOR for futher details.