BGT-S Series tanktop mounted return line filters feature pre-filtration by means of a magnet column and a full flow bypass with low hysteresis. Thanks to the 'in-to-out' filter principle, oil cannot leak back into the system.
BGTS return in-tank filters feature Parker's exclusive magnetic prefiltration core which collects ferromagnetic particles from fluid upstream of the filter element. This feature alone could save hundreds of dollars a year by protecting costly equipment from increased wear and malfunction by assuring that the fluid is as pure as possible when it leaves the filter. Even during bypass due to cold start up, contaminant is collected by the magnetic core, a feature of importance on any fluid power system.
Technical Features
Flow
Rate
Maximum Operating Pressure
Element Collapse Rating
Micron Rating
Filter
Media
Working Temperature
Ports
Up
to
2000 l/min
10 Bar
10 Bar
From 3µm
to
40µm
Cellulose,
HPFE Glass Fibre and
Stainless Steel Mesh