Arlon's high pressure filters are specified worldwide for industrial, mobile, marine and mining applications.
High performance, low hysteresis bypass valve assures quick return to the closed position following cold starts or other short-term bypass conditions. Result: the best filter performance and protection for your system. The location of bypass valve is 90º to the flow stream, which prevents unwanted valve operation and helps cushion the effect of systems shocks (when compared with in-line valve location).
The bypass condition is indicated by the appearance of a red band under the transparent dome. The indicator has 360º visibility for easy viewing.
Technical Features
Flow
Rate
Maximum Operating
Pressure
Element
Collapse
Rating
Micron
Rating
Filter
Media
Working Temperature
Ports
Up to
250 l/min
414 Bar
20 Bar (220 Bar High Strength Disposable)
From 3µm
to 75 µm
Cellulose,
HPFE Glass Fibre and
Stainless Steel Mesh